D Measuring ranges for TME 400-VMF/
TME 400-VCF
Values for custody transfer metering according to MID approval with
natural gas
DN
[mm]
G-
value
Q
max
[m³/h]
Flow [m³/h]
at p
min
=1 bar
[1]
Q
min
[m³/h] depending on operating pressure p
min
[bar(g)]
MR
[2]
1:20
MR 1:30
MR 1:50
MR 1:80
MR 1:100
MR 1:120
MR 1:160
Q
t
Q
min
Q
min
p
min
Q
min
p
min
Q
min
p
min
Q
min
p
min
Q
min
p
min
Q
min
p
min
50
65
100
20
5
[3]
80
100
160
32
8
[3]
5
15
3,2
50
160
250
50
12,5
8
3
5
10
3,2
50
250
400
80
20
13
3
8
10
5
25
100
160
250
50
12,5
8
3
5
25
250
400
80
20
13
3
8
10
5
25
400
650
130
32
20
3
13
4
8
10
6,5
15
5
25
150
400
650
130
32
20
3
13
10
8
25
6,5
40
650
1000
200
50
32
3
20
4
13
10
10
15
8
25
1000
1600
320
80
50
3
32
4
20
10
16
15
13
25
10
40
200
1000
1600
320
80
50
3
32
4
20
10
16
15
13
25
10
40
1600
2500
500
125
80
3
50
4
32
10
25
15
20
25
16
40
250
1000
1600
320
80
50
3
32
10
20
25
16
40
1600
2500
500
125
80
3
50
4
32
10
25
25
20
40
16
60
2500
4000
800
200
130
3
80
4
50
10
40
25
35
40
25
60
300
2500
4000
800
200
130
3
80
4
50
10
40
25
35
40
25
60
4000
6500
1300
320
220
3
130
10
80
25
65
40
55
60
40
80
4000-45
6500
1300
320
220
3
130
10
80
25
65
40
55
60
40
80
[1]
p = 1 bar; means atmospheric pressure
[2]
MR = Measuring range = Q
max
/ Q
min
[3]
MR: 1:20; for p ≥ 3 bar(g)