8. FAULT INFORMATION
8.1. ALARM MESSAGES
In the event of a breakdown during operation the machine stops automatically and alarm messages appear on the
display.
The table lists the displayed messages, the type of problem, the causes and possible solutions.
Important
For these operations a precise technical expertise or ability is required; therefore, these operations must
be exclusively performed by qualified personnel with certified experience acquired in the specific field of
intervention.
Emergency mushroom-head
button alarm.
Emergency mushroom-head
button pressed
Reset the button and press the
“Reset” button
An obstacle has been detected
along the trajectory during the
spool carriage downstroke.
Remove the obstacle and
press the “Reset” button
Hand pallet truck emergency
An obstacle has been detected
on the pallet loading/unloading
ramp.
Remove the obstacle and
press the “Reset” button
Intervention of safety barriers or
open door
Remove the obstacle and
press the “Reset” button
Inverter alarm:
1. Table
2. Carriage
3. Stretch
Contact technical support
The film has broken or spool is
finished
Insert the film or replace spool.
A fault or an obstacle is
preventing the table from
moving
Solve the fault or remove the
obstacle and press the “Reset”
button
Error alarm
Communication
Contact technical support