EasyManua.ls Logo

Robox RBX01 - Page 76

Robox RBX01
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7676
www.cel-robox.com
5.0 AutoMaker Soware
Enable Automatic Cooling
This setting is used to enable or disable automatic cooling for 3D prints.
AutoMaker™ uses one of two methods to control cooling - it can either
increase the fan speed or slow down the time to print a layer. The choice of
which method is used is controlled by ‘Enable Fan if Layer Time <’ and ‘Go
Slow if Layer Time <’.
Minimum Fan Speed (%)
This sets the minimum fan head speed as a percentage of full power.
Maximum Fan Speed (%)
This sets the maximum fan head speed as a percentage of full power.
Bridges Fan Speed (%)
This sets the fan speed which is used when printing bridges as a percentage
of full power.
Disable Fan for First n Layers
This disables the head fan when printing the first n layers, this can help with
adhering the first layer to the bed. It is recommended to leave it o for the
first 1 or 2 layers.
Enable Fan if Layer Time < (seconds)
This will increase the fan speed to maximum if the layer time takes less than
the specified value in seconds.
Go Slow if Layer Time < (seconds)
This will slow down the print speed if the layer time takes less than the
specified value in seconds.
Minimum Print Speed (mm/s)
This setting is a lower limit on how slowly a layer can be printed in
millimetres per second.
Help Text
This box displays a brief explanation of the setting which is highlighted
(changes on mouseover).