EasyManua.ls Logo

Rohde & Schwarz CMU 300 - Page 165

Rohde & Schwarz CMU 300
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CMU RF: Power vs. Time Measurement
1100.4903.12 4.47 E-10
Resolution
Bandwidth
Resolution Bandwidth defines the resolution bandwidth of the measurement filter.
The nominal resolution bandwidth is the 3-dB bandwidth of the Gaussian meas-
urement filter. From a list discrete bandwidths between 10 Hz and 1 MHz can be
selected. The frequencies in the list are given by 1x10
n
Hz, 2x10
n
Hz, 3x10
n
Hz,
5x10
n
Hz where n=1 to 5. In addition the value 1 MHz can be selected.
Resolution bandwidths for the analyzer and the Spectrum measurement can be set
independently (see also p. 4.49).
Remote control
[SENSe:]POWer:FREQuency:BANDwidth[:RESolution] <Bandwidth>
[SENSe:]POWer:FREQuency:BWIDth[:RESolution] <Bandwidth>
Grid
The Grid checkbox switches The grid in the graphical test diagram on or off.
Remote control