Loading...
CMU Measurement Control
1100.4903.12 5.39 E-8
Counting Measurements
Stop condition: NONE
300
INITiate
RDY
RUN
CONTinue
FETCh?
300
300
RUN
RUN
STEP STEP
FETCh?
CONTinue
FETCh?
A counting measurement comprising 3 counts of
measurements, each about a statistics cycle of
300 evaluation periods, is performed. The meas-
urement is started with the INITiate command.
The results can be queried using the SAMPle...?
(status RUN, STEP or RDY) or FETCh...?
(status STEP or RDY) commands. The measure-
ment is configured via:
CONFigure:<meas_obj>:CONTrol <type>,300
CONFigure:<meas_obj>:CONTrol:REPetition
3,NONE,<Stepmode>
The STEP status occurs only if the stepping mode
is set (<Stepmode> = STEP). In this case, the
next cycle must be restarted via the CONTinue
command.
Stop condition: SONerror
300
INITiate
RUN
CONTinue
FETCh?
120
300
RUN
STEP
RDY
FETCh?
A counting measurement comprising counts of
measurements, each about a statistics cycle of
300 evaluation periods, is performed. The meas-
urement is started with the INITiate command.
The results can be queried using the SAMPle...?
(status RUN, STEP or RDY) or FETCh...?
(status STEP or RDY) commands. The measure-
ment is configured via:
CONFigure:<meas_obj>:CONTrol <type>,300
CONFigure:<meas_obj>:CONTrol:REPetition
3,SONerror,<Stepmode>
The STEP status occurs only if the stepping mode
is set (<Stepmode> = STEP). In this case, the
next cycle must be restarted via the CONTinue
command.

Table of Contents