Measurement Control  CMU 
1100.4903.12 5.34  E-8 
Generator Status 
The generator status can be queried by means of the FETCh...? command: 
 
FETCh command 
FETCh:<meas_obj>:STATus? 
Return the current generator status. The FETCh... command can be used to 
poll the generator status. The FETCh... query returns one of the following gen-
erator states:  
OFF  generator is in the OFF state (default status after *RST or due to 
ABORt... command). 
RUN  generator running (RUN state after INITiate... command). 
ERR  generator is in the OFF state because it could not be started with an 
INITiate... command for lack of resources (e.g. the RF connec-
tor is already in use by another generator).  
 
 
 
Measurement Statistics 
The repetition mode defines how many evaluation periods are measured if the measurement is not 
stopped explicitly (measurement control commands STOP..., ABORt...) in the meantime. In case 
of remote control the three repetition modes Single Shot, Continuous and Counting are available 
(Counting is not available in manual control, see Chapter 3).  
Table 5-7   Repetition mode in remote control 
Repetition mode  Description  Command 
Single Shot  The measurement is stopped after one 
evaluation period, i.e., after evaluation of 
the trace over the whole time/frequency 
range. 
CONFigure:<meas_obj>:CONTrol:REPetition  
SINGleshot, <StopCondition>, <Stepmode> 
(in RF: <meas_obj> = POWer | SPECtrum) 
Continuous  The measurement is continued until 
explicitly stopped. Results are valid after 
one evaluation period and updated after 
the next evaluation period has been 
terminated. 
CONFigure:<meas_obj>:CONTrol:REPetition  
CONTinuous, <StopCondition>, <Stepmode> 
(in RF: <meas_obj> = POWer | SPECtrum) 
Counting  Repeated single shot measurement with 
a definite number of evaluation periods. 
The stepping mode (<Stepmode> = 
STEP | NONE) determines whether the 
measurement is stopped after each 
evaluation period or not, see section 
Measurement Control Com-
mands and States
 on page 5.28. 
CONFigure:<meas_obj>:CONTrol:REPetition  
1 ... 10000, <StopCondition>, <Stepmode> 
(in RF: <meas_obj> = POWer | SPECtrum) 
(A counting measurement with 1 evaluation period is equiva-
lent to a single shot measurement.) 
 
The statistical evaluation is more refined for the digital network tests, see the relevant operating manu-
als. In particular, the counting mode is extended by introduction of statistics cycles consisting of an 
integer number of evaluation periods.