RF Measurements CMU
1100.4903.12 6.58 E-10
CONFigure:WPOWer:CONTrol:REPetition <Repetition>,<StopCond>,<Stepmode> Test cycles
<Repetition>
Description of parameters Def. value Def. unit
CONTinuous |
SINGleshot |
1 ... 10000
Continuous measurement (until STOP or ABORT)
Single shot measurement (until Status = RDY)
Multiple measurement
(counting, until Status = STEP | RDY)
SING
<StopCond>
Description of parameters Def. value Def. unit
SONerror |
NONE
Start measurement in case of error (stop on error)
Continue measurement even in case of error
NONE –
<Stepmode>
Description of parameters Def. value Def. unit FW vers.
STEP |
NONE
Interrupt measurement after each statistics cycle
Continue measurement according to its rep. mode
NONE – V3.10
Description of command
This command determines the number of statistics cycles, the stop condition and the stepping mode for the
measurement.
Note: In the case of READ commands (READ:...), the <Repetition> parameter has no effect; the measure-
ment is always stopped after a single shot.
Measured Values – Subsystem WPOWer?
The subsystem WPOWer? retrieves the results of the wideband power measurement.
READ[:SCALar]:WPOWer? Start single shot measurement and return results
FETCh[:SCALar]:WPOWer?
Read out measurement results (unsynchronized)
SAMPle[:SCALar]:WPOWer?
Read out measurement results (synchronized)
Return
Description of parameters Def. value Def. unit FW vers.
0 dBm to +55 dBm
–10 dBm to +35 dBm
–35 dBm to +2 dBm
Maximum RF power at RF1
Maximum RF power at RF2
Maximum RF power at RF 4 IN
NAN dBm V3.10
Description of command
These commands are always queries. They start the measurement of the maximum RF power (peak power, not
averaged) and return the result.

Table of Contents