CMU  Audio Generator and Analyzer (with Option CMU-B41) 
1100.4903.12 6.79  E-10 
Tolerance values – Subsystem MULTitone:...LIMit 
The subsystem MULTitone:...LIMit defines tolerance values for the Multitone measurement. The sub-
system corresponds to the Limits tab of the popup menu Multitone Configuration. 
 
CONFigure:MULTitone:AF1Channel:LIMit:LINE:ASYMmetric:UPPer 
CONFigure:MULTitone:AF2Channel:LIMit:LINE:ASYMmetric:UPPer 
  <Limit_1>, <Enable_1>, ... <Limit_20>, <Enable_20>  Upper Limit, Overall
<Limit_nr> 
Description of parameters  Def. value  Def. unit   
–80 dB to +80 dB,  Upper limit line at tone <nr>  See below  dB   
<Enable_nr> 
Description of parameters  Def. value  Def. unit  FW vers. 
ON | OFF  Enable upper limit line at tone <nr>  ON  –  V3.0 
Description of command 
This command configures the upper limit lines and enables the limit check at the 20 test tones that can be de-
fined via CONFigure:MULTitone:AF1Channel:TONE<nr>.  
By default, the limit check is switched on at all tones and the following limit lines apply: 
Tone <nr>  Limit Line/[dB]  Enable   Tone <nr>  Limit Line/[dB]  Enable
 1  –9.5  ON  11  +5.6  ON 
 2  –6.2  ON  12  +6.3  ON 
 3  –3.8  ON  13  +6.9  ON 
 4  –1.9  ON  14  +7.5  ON 
 5  –0.3  ON  15  +8.0  ON 
 6  +1.0  ON  16  +8.6  ON 
 7  +2.1  ON  17  +9.1  ON 
 8  +3.1  ON  18  +9.6  ON 
 9  +4.0  ON  19  +10.0  ON 
 10  +4.8  ON  20  +10.5  ON
 
 
CONFigure:MULTitone:AF1Channel:TONE<nr>:LIMit:LINE:ASYMmetric:UPPer 
CONFigure:MULTitone:AF2Channel:TONE<nr>:LIMit:LINE:ASYMmetric:UPPer 
 <Limit>, <Enable>  Upper Limit, Single Point
<Limit> 
Description of parameters  Def. value  Def. unit   
–80 dB to +80 dB,  Upper limit line at tone <nr>  See below  dB   
<Enable> 
Description of parameters  Def. value  Def. unit  FW vers. 
ON | OFF  Enable upper limit line at tone <nr>  ON  –  V3.0 
Description of command 
This command configures the upper limit and enables the limit check at one of 20 test tones that can be defined 
via CONFigure:MULTitone:AF1Channel:TONE<nr>. The test tones are numbered by <nr> = 1 to 20. The 
default limits at all test points are quoted in the previous command.