Measurements
R&S
®
FSW
210User Manual 1173.9411.02 ─ 19
Range Start / Range Stop...........................................................................................210
Fast SEM.................................................................................................................... 211
Filter Type................................................................................................................... 211
RBW............................................................................................................................211
VBW............................................................................................................................211
Sweep Time Mode...................................................................................................... 211
Sweep Time................................................................................................................ 212
Ref. Level....................................................................................................................212
RF Att. Mode...............................................................................................................212
RF Attenuator..............................................................................................................212
Preamp........................................................................................................................212
Transd. Factor.............................................................................................................212
Limit Check <n>.......................................................................................................... 213
Abs Limit Start/Stop <n>............................................................................................. 213
Rel Limit Start/Stop <n>..............................................................................................213
Multi-Limit Calc <n>.................................................................................................... 214
Minimum Sweep Points...............................................................................................214
Insert before/after Range............................................................................................ 214
Delete Range.............................................................................................................. 215
Symmetric Setup.........................................................................................................215
Range Start / Range Stop
Sets the start frequency/stop frequency of the selected range.
In order to change the start/stop frequency of the first or last range, respectively, select
the appropriate span with the SPAN key. If you set a span that is smaller than the over-
all span of the ranges, the measurement includes only the ranges that lie within the
defined span and have a minimum span of 20 Hz. The first and last ranges are adap-
ted to the given span as long as the minimum span of 20 Hz is not violated.
Spectrum Emission Mask (SEM) Measurement