29
Advanced Use
Retrigger Cancel
1–16
Altered waveforms may cause inadvertent
sounding at Point A in the following figure
(This is called retrigger).
fig.05-18_80
This occurs in particular at the decaying edge
of the waveform. Retrigger Cancel detects
such distortion in and prevents retriggering
from occurring.
Although setting this to a high value
prevents retriggering, it then becomes easy
for sounds to be omitted when the drums
played fast (roll etc.). Set this to the lowest
value possible while still ensuring that there
is no retriggering.
You can also eliminate this problem
of retriggering with the Mask Time
setting. Mask Time does not detect
trigger signals if they occur within
the specified amount of time after
the previous trigger signal was
received. Retrigger Cancel detects
the attenuation of the trigger signal
level, and triggers the sound after
internally determining which
trigger signals were actually
generated when the head was
struck, while weeding out the other
false trigger signals that need not
trigger a sound.
Making the settings
While repeatedly striking the pad, raise the
Retrigger Cancel value until retriggering no
longer occurs.
Crosstalk Cancel
OFF, 20–80 (adjustable in increments of 5)
When two pads are mounted on the same
stand, the vibration produced by hitting one
pad may trigger the sound from another pad
unintentionally (This is called crosstalk.) You
can avoid this problem by adjusting
Crosstalk Cancel on the pad that is sounding
inadvertently.
If the value is set too high, then when two
pads are played simultaneously, the one that
is struck less forcefully will not sound. So be
careful and set this parameter to the
minimum value required to prevent such
crosstalk. With a setting of OFF, crosstalk
prevention does not function.
In some cases, you can prevent
crosstalk between two pads you
have connected by increasing the
distance between the pads or by
raising the Threshold value.
You cannot prevent crosstalk from
pads connected to other drum
sound modules. Try increasing the
distance between such pads, or raise
the Threshold.
Making the settings
When hitting the pad connected to the
Trigger Input 1, the pad connected to the
Trigger Input 2 also sounds:
Set the Crosstalk Cancel for the pad
connected to the Trigger Input 2 while
striking the pad connected to the Trigger
Input 1. Striking the pad connected to the
Trigger Input 1, raise the Crosstalk Cancel
setting for the pad connected to the Trigger
Input 2 from OFF until crosstalk no longer
occurs. As this value is raised, the pad
connected to the Trigger Input 1 will be less
prone to receive crosstalk from the other
pad.
Time