NK Series User Guide (1.0) Appendix A: Connectors and Pinouts • 6–5
Figure 6.10 Pinouts for Inputs and Outputs on the NK-D64/110
Power Connector - DB-9 (All NK-16 and NK-32 Routers)
Figure 6.11 shows the DB-9 connector port on the rear of the routers and can be used to connect GPI alarms.
Figure 6.11 DB-9 Connector Port for GPI Alarms
Machine Control DB-9 Pinouts (NK-M16 and NK-M32)
Figure 6.12 shows the pinouts for DB-9 connections on the NK-M16 and NK-M32 Machine Control routers.
The Machine Control DB-9 pinouts are dependent on which mode (Master or Slave) is being used.
13
1
G
-+
G
-+++
++++
GG
GGGG
--
----
2
10
4
12
6
14
8
16
1
9
3
11
5
13
7
15
18
26
20
28
22
30
24
32
17
25
19 21 23
27 29 31
34 36 38 40
42 44
46
48
50
52
54 56
58 60 62 64
33 35 37 39
41 43 45 47
49 51 53 55
57 59 61 63
1
2
3
4
5
6
7
8
9
DB-9 Male
(External View)
1
6
2
7
3
8
4
9
5
GND
GND
+15V
+15V
-15V
-15V
RCP Power Fail
Matrix Power Fail