Programming the AC-Q74
AC-Q74 Installation and Programming Manual 31
11.9.4 Enrolling Primary and Secondary Codes using
the Standard Method
1. Enter Programming Mode.
2. Press “7” to enter Menu 7
The Door LED turns orange.
3. Enter the 3-digit User Slot number
between 001 and 500 to which you wish
to enroll a Primary or Secondary code.
For example, the User Slot 003 represents
User #3.
If the selected slot has no Primary
code, the Mode LED flashes green,
indicating that the controller is ready
to accept a Primary code.
If the selected slot already has a
Primary code but no Secondary code
,
the Mode LED flashes red, indicating
that the controller is ready to accept
a Secondary code.
If the selected slot already has a Primary and Secondary code,
you hear a long beep and the controller returns to Normal
Mode.
4. Present a Proximity Card or enter the 4-digit PIN that you want to
assign as the Primary or Secondary code for this slot number.
If the Proximity Card or PIN that is entered is valid, the Mode LED
stops flashing and then the controller is ready for you to enter the
next 3-digit slot number (see Step 3) that you want to assign a
code to, or press the#” key to move to the next slot number
(see Step 4). If you do not wish to continue enrolling codes, press
the “#” key twice and the controller returns to Normal mode.
Mode Door
GREEN
Mode Door
ORANGE
?
?
?
Mode Door
GREEN
ORANGE
Mode Door
RED ORANGE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AC-Q74 and is the answer not in the manual?

Rosslare AC-Q74 Specifications

General IconGeneral
BrandRosslare
ModelAC-Q74
CategoryCard Reader
LanguageEnglish

Related product manuals