PS-25T with Enclosures
40 AC-Q74 Installation and Programming Manual
13. PS-25T with Enclosures
13.1 PS-A25T
The PS-A25T enclosure includes a built-in speaker and enough room
for a CE or UL approved transformer.
Figure 4: PS-A25T
13.1.1 PS-A25T
The PS-A25T comes with a built-in CE approved transformer. That is
Class II Rated (Double insulated) and contains thermal fuse protection.
Max: 125 C, 1A. See transformer specifications below:
Input
230 VAC ~ 50Hz, 0.14 A
Output
16 VAC ~ 1.5A, 40 VA
Certifications
CE
Compliance
A1:1998
EN 61558-1:1997
EN 61558-2-6:1997
13.2 PS-C25T/25TU
The PS-C2 and PS-C25TU enclosures include a built-in speaker and
enough room for a CE or UL approved transformer as well as a lead
acid backup battery (up to 7 AH).