INSTRUCTION, USE AND
MAINTENANCE MANUAL
GB
Page 49 of 57
- Press push button .
On the monitor the next screen page will be dis-
played:
Measure the exact diameter of a rim (see Fig. 49) and
place it on the screen on the monitor by pressing the
or buttons.
Fig. 49
- Fit the measured wheel on the balancer and lock it
on the mandrel.
- Turn the gauge ferrule (Fig. 50 ref. 1) on the inner
edge of the wheel upwards (see Fig._50).
Fig. 50
1
- Press button to end the operation. On the
monitor the next screen page will be displayed:
The calibration of the distance-diameter caliper is
finished.
Calibration of external data gauge (optional)
Press the button
(Fig. 46 ref. 2) to display the
following screen page on the monitor:
TO PERFORM THIS CALIBRATION,
THE MANDREL MUST BE UNLOAD-
ED (NO WHEEL OR ACCESSORIES
MOUNTED ON IT).
Move the tip of the width measuring device (Fig. 51-
52 ref. 1) in line with the mandrel edge (Fig. 51-52
ref. 2).