d04924.fm
INSTALLATION MANUAL
BRP-Powertrain
Effectivity: 912 Series
Edition 2/Rev. 0
75-00-00
page 20
August 01/2012
Fig. 9 08319
3.2.1) Overflow bottle
General note See Fig. 10.
The system also needs an overflow bottle in which surplus coolant is col-
lected and returned to the coolant circuit during the cooling down period.
NOTE: For proper operation ensure that the hose to the overflow
bottle is as short as possible.
Overflow bottle
requirements
- Transparent material
- Temperature resistant from -40 °C to +130 °C (-40 °F to 266 °F)
- 100 % resistant to glycol and suitable for all other antifreeze agents
- Volume approx. 0.5 l (.13 USgal)
- With vent (6), diameter 2.5 mm (0.1 in.)
NOTE: See also SB-912-039 “Modification of the overflow bottle“,
latest issue.
NOTE: The overflow bottle should be furnished with a label indicat-
ing function and content.
Capacity
Installation
4 Water inlet elbow
5 Overflow bottle
6 Purging
Part Function
WARNUNG
NOTICE
To ensure proper operation of the cooling system, the
suction height between overflow bottle and expansion
tank must not exceed 250 mm (10 in.).
WARNUNG
WARNING
Non-compliance can result in serious injuries or death!
The overflow bottle must never be empty, otherwise air
will be sucked into the cooling circuit; this can have a
negative effect on the safe operation of the engine.
WARNUNG
NOTICE
The overflow bottle and its supply and discharge must
not be installed close to the exhaust system, as emerg-
ing coolant can be flammable under certain conditions.

Table of Contents

Other manuals for Rotax OM-912

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax OM-912 and is the answer not in the manual?

Rotax OM-912 Specifications

General IconGeneral
BrandRotax
ModelOM-912
CategoryEngine
LanguageEnglish

Related product manuals