3.5 USER SETTINGS
3.5.1 Floor pump > It is possible to turn o the circulation pump, but this will result in no heating/cooling.
Default ON.
3.5.2 Heating > ON – this function enables the user to include/exclude the zone in/from the heating algorithm.
> Schedule settings – this function enables the user to choose the schedule which will apply in a zone (local
schedule, global schedule G-1 to G5) during heating, if the zone operation is based on a schedule.
> Constant temperature – this function enables the user to dene a separate pre-set temperature that will apply in
the zone during heating, if the zone operation is based on a constant temperature.
3.5.3 Cooling > This menu is only visible if cooling is ON (Fitters menu).
> ON – this function enables the user to include/exclude the zone in/from the cooling algorithm.
> Schedule settings – this function enables the user to choose the schedule which will apply in a zone (local
schedule, global schedule G1 to G5) during cooling, if the zone operation is based on a schedule.
> Constant temperature – this function enables the user to dene a separate pre-set temperature that will apply in
the zone during cooling, if the zone operation is based on a constant temperature.
> Humidity protection – this function is used to protect the oor against dewfall (condensation). If the humidity in a
given zone is higher than “Max humidity” value dened in the tter’s menu, cooling will be disabled in this zone
untill the humidity value drops below the pre-dened.
3.5.4 Temperature settings > This function enables the user to dene pre-set temperatures for the three operation modes (Comfort mode,
Economical mode and Holiday mode) locally for the zone.
3
Operation
mode
Local
schedule
Select Preview Edit
Global
schedule
G1 - G5
Select Preview Edit
Constant
temperature
With time
limitation
User
settings
Floor pump
On Off
Heating
On
Schedule
settings
Constant
temperature
Temperature
settings
Temp.
comfortable
Economical Holidays
Zones
1-8
Floor
heating
Registration Information
Operation
mode
Off
Floor
protection
Comfort
Max
temperature
Hysteresis Calibration