Risk of fatal electric shock from touching live connections. Ensure power is off before work.
Incorrect cable connections can lead to controller damage.
Connect actuators, pump, and any additional devices to the master controller.
Switch on the controller and select the preferred user interface language.
Set the current time and date manually or automatically via internet connection.
Configure temperature sensors and room regulators for zone temperature control.
Displays the current day of the week and the system time.
Shows status of zones, including active heating/cooling and sensor connection.
Displays actual room and floor temperatures, and set point temperatures.
Indicates the current mode for each zone (e.g., Constant, Schedule, Holiday).
Icons showing pump/heatsource activity, signal strength, and thermostat battery level.
Shows the outdoor temperature if an external sensor is connected.
Provides access to all controller functions and settings via the main menu.
Select system-wide modes like Normal, Holiday, Economy, and Comfort.
Configure parameters for individual zones, including sensor type and operation mode.
Customize user settings for heating, cooling, floor pump, and temperature per zone.
Register floor sensors with thermostats for floor heating control.
View settings and status of the connected floor sensor.
Set floor sensor mode: OFF, Floor protection, or Comfort.
Define maximum and minimum floor temperatures for protection and comfort.
Set hysteresis for floor temperature to prevent rapid cycling.
Calibrate the floor sensor for accurate temperature readings.
Add and control Roth Softline wireless radiator actuators for heating zones.
Remove registered actuators from the system.
View status, software version, and wireless signal of actuators.
Adjust specific settings for radiator actuators, including Sigma control.
Enables smooth control of radiator actuators via valve closing level settings.
Door closing based on temperature/humidity limits to protect floor construction.
Defines actuator response during sensor or communication failure alarms.
Add and control Roth Softline wireless window contacts for zones.
Remove registered window sensors from the zone.
View status, software version, and wireless signal of window sensors.
Adjust specific settings for window sensors, including delay time.
Set delay for sensor response to window opening to affect heating/cooling.
Register the connection between master and extension controllers.
Enable or disable the connection to a specific extension controller.
View and modify zone settings on an extension controller.
Check the signal strength between master and extension controllers.
Turn on the weather-based control function using an external sensor.
Register the external temperature sensor to the master controller.
Choose between wireless or wired NTC external sensor types.
Monitor signal strength and battery level of wireless external sensors.
Displays the actual measured outdoor temperature.
Configure weather control parameters like average temp and threshold.
Configure screensaver to prevent burn-in and manage button sound feedback.
Switch display views and adjust screen contrast for readability.
Adjust screen brightness and configure the screen fade-to-sleep behavior.
Set the idle time before the screen automatically goes to sleep.
Configure the WiFi module for remote system control via the internet.
Configure an external repeater to improve signal strength and range.
Register and configure additional contacts like valve modules for system integration.
Set operation modes for pump and potential-free contacts.
Control relays and actuators for radiator zones 1 through 8.
Configure operation modes, schedules, and time limits for DHW.
Set up OpenTherm communication for boiler modulation and efficiency.
Activate weather-based control using external sensor data for optimized heating.
Manually switch between heating and cooling or use automatic switching.
Set maximum humidity to protect floors from condensation during cooling.
Configure cooling parameters like ON/OFF, schedules, and constant temperatures per zone.
Define and edit separate time schedule settings for individual zones.
Define and edit global time schedules that apply to all zones.
Reactivate a previously set schedule directly from a room thermostat.
Deactivate time schedules and revert to continuous mode (CON).
Edit specific time periods and set temperatures within schedules.
Define optional separate schedule settings for specific days like weekends.
Assign specific days to schedule 'Part of the week 1' or 'Part of the week 2'.
Specifications for the Roth Softline Controller 8 ch, master.
Specifications for the Roth Softline Controller 8 ch, extension.
Technical specifications for the Roth Softline Standard room thermostat.
Technical specifications for the Roth Softline WiFi Internet module.