XVII. TECHNICAL DATA
Roth Soline Controller 8 ch, master HVAC no. 7466397028
Supply voltage 230V AC
Energy consumption 6 W
Number of outputs and voltage 18 (NC/NO), 230V AC
Max. sustained load 18 thermal actuators (0.3 A)*
(2 channels of 3 actuators and 6 of 2 actuators)
Wireless channels 8 thermostat/sensors
6 radiator actuators (each zone)
6 window contacts (each zone)
Protection class I (EN60730)
Transmission frequency 868 MHz
Range (up to) 30 m (in ordinary building)
Max. load pump relay 230V and 0.5 A
Max. load potential-free relay 1A
Power supply cable 85 cm
Ambient temperature 5 - 50°C
Ambient humidity < 80% RH
Storage/transport temperature -20 - +50°C
Degree of protection IP20 (EN60529)
Fuse glass fuse WT 6.3A (5 x 20mm)
Approvals CE 2014/53/EU
* If required up to 4 actuators can be connected to the same output/zone (32 actuators in total on the controller).
Meaning: An output with 2, 3 or 4 terminals can all be connected with up to 4 actuators.
Roth Soline Controller 8 ch, extension HVAC no. 7466397038
Supply voltage 230V AC
Energy consumption 6 W
Number of outputs and voltage 22 (NC/NO), 230V AC
Max. sustained load 22 thermal actuators (0.3 A)*
(3 channels of 4 actuators and 5 channels of 2 actuators)
Wireless channels 8 thermostat/sensors
6 radiator actuators (each zone)
6 window contacts (each zone)
Protection class I (EN60730)
Transmission frequency 868 MHz
Range (up to) 30 m (in ordinary building)
Max. load pump relay 230V and 0.5 A
Max. load potential-free relay 1A
Power supply cable 85 cm
Ambient temperature 5 - 50°C
Ambient humidity < 80% RH
Storage/transport temperature -20 - +50°C
Degree of protection IP20 (EN60529)
Fuse glass fuse WT 6.3A (5 x 20mm)
Approvals CE 2014/53/EU
* If required up to 4 actuators can be connected to the same output/zone (32 actuators in total on the controller).
Meaning: An output with 2, 3 or 4 terminals can all be connected with up to 4 actuators.