It is possible to verify the current setting of the RTX3741 dongle in
the PC Tool;
Headset (Portable Part)
Enables DECT access for a USB desktop phone on the RTX VoIP
System;
Slider is placed at the top;
It is possible to verify the current setting of the RTX3741 dongle in
the PC Tool;
6.3 LED Patterns
The LED support different kinds of patterns, such as fast blink, slow blink, normal blink and breathing:
LED PATTERN
DEFINITION
BLINK
ON/OFF
BREATHING
OFF-ON-OFF slowly
6.4 LED Indication
The following table shows the LED indication for different status of the DECT dongle.
FUNCTION
STATUS
LED
PATTERN
SYSTEM
Dongle reset started
Red, Blue and Green
Blink 3 times
DECT
CONNECTION
Registration, In progress
Blue
Blink alternately
Registration, Success
Blue and Green
Blink 3 times
Registration, Failed
Blue and Red
Blink 3 times
Master headset registered
Blue
ON
Master headset lost link
Red
ON
Ringing
Green
Blink
CALL
Talk or Hold
Green
ON
Conference or intrusion call
Green
Breathing
6.5 Key Configuration / User Interface
The button on the RTX3741 Dongle is used for registration and deregistration of the headsets. All setup is
done using the PC Setup tool. Furthermore, all call-related controls are managed via the headset controls
and/or desk phone/PC. The call is initiated from the Soft Call Client running on the PC/laptop.
6.6 Factory Reset
To reset your dongle, press the button for 15 seconds or until all 3 LED (red, blue, green) turn on and then
off. Then release the button and your device will proceed to reset its settings.