Page #232 background image
222
Port Join Time Leave Time LeaveAll Time Applicant Registrar Restricted
---- --------- ---------- ------------- --------------- --------- ----------
1 20 60 1000 Normal Normal Enable
2 20 60 1000 Normal Normal Enable
3 20 60 1000 Normal Normal Enable
4 20 60 1000 Normal Normal Enable
5 20 60 1000 Normal Normal Enable
6 20 60 1000 Normal Normal Enable
7 20 60 1000 Normal Normal Enable
8 20 60 1000 Normal Normal Enable
9 20 60 1000 Normal Normal Enable
10 20 60 1000 Normal Normal Enable
:
:
:
22 20 60 1000 Normal Normal Disable
23 20 60 1000 Normal Normal Disable
24 20 60 1000 Normal Normal Disable
set timer
Syntax:
set timer <port> <JoinTime> <leaveTime> <leaveAllTime>
Description:
To set gvrp join time, leave time, and leaveall time for each port.
Argument:
<port> : port range, syntax 1,5-7, available from 1 to 24
<JoinTime>: join timer, available from 20 to 100
<LeaveTime>: leave timer, available from 60 to 300
<LeaveAllTime>: leaveall timer, available from 1000 to 5000
Leave Time must equal double Join Time at least.
Possible value:
<port> : 1 to 24
<JoinTime>: 20 to 100
<LeaveTime>: 60 to 300
<LeaveAllTime>: 1000 to 5000
Example:
GS-2224L(gvrp)# set timer 2-8 25 80 2000
show
Syntax:
show
Description:
To display the gvrp configuration.
Argument:
None
Possible value:
None
Example:
GS-2224L(gvrp)# show
GVRP state: Enable
Port Join Time Leave Time LeaveAll Time Applicant Registrar Restricted

Table of Contents