for Royal Cappucc.)
58,000 - 65,500 +/- 1 The pump delivery rate is adjusted
in relation to the HOT WATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under HOT WATER PUMP
ADJUSTMENT.
TURBOWATER
FLOW (l/h) 20
(Only in System 2: ON)
only Royal Cappucc.)
6 - 34 1/h
+/- 2 1/h The pump delivery rate for
turbowater can be expressed in
litres per hour.
(only active when System 2 steam
cycle is active; mixes with hot
water System 1 and System 2)
TURBOWATER
PUMP ADJUST. 63000
(Only in System 2: ON)
(only Royal Cappucc.)
58,000 - 65,500 +/- 1 The pump delivery rate is adjusted
in relation to the TURBOWATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under TURBOWATER
PUMP ADJUSTMENT.
Only when System 2 is activated.
WATER RESERVE
NUMBER
No. of PULSES
NUMBER
From Version: 2003
1-2500
When the water tank is full, the
value from WATER RESERVE
STOP is applied. The flow meter
pulses are counted from when the
reed switch is switched and
deducted from the value. If a
beverage is chosen for which the
saved pulse number is higher than
the remaining pulses, the message
FILL WATER TANK appears.