ROYAL 6. FAULTS
Saeco International Group REV.4 SEPT.2003 Page 1/3
1. Faults:
The following table indicates the most common faults, listed by component.
Part
Fault Cause
SI on mains filter defective
Main switch defective
Door switch defective
Electronic system defective
Electronics
Does not function
No display
KTY defective Cold coffee
Standby LED lights up
continuously
Electronic system defective
KTY defective Temperature differences
No froth
Electronic system defective
Heating - Interruption
Heating plug connection
Thermal fuse
Heating
Heating remains cold
Heating indicator remains lit up
Fusible cut-out
(No grinder function)
Doser switch constantly
activated / Dirt
Water instead of coffee
Defective doser rinse
Dose quantity too low Weak coffee
Dose chamber - coffee residues
Doser switch does not work
Doser flap does not close
Doser
Recurring indicator
COFFEE BEANS LOW
- Brewing unit overfull
- Gearmotor obstructed
Electronic system defective