Loading...
DOCUMENT SSE-0000077399-01 - VERSION 1.0 - MAY 2010 71
S
AGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
MORPHOACCESS® J SERIES User Guide Anti-tamper and anti-pulling switches
TERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATION
7. Anti-tamper and anti-pulling
switches
Description
The MorphoAccess
®
J Series, like the MorphoAccess
®
500 Series, is able to
detect two kinds of unsual events:
the front glass is removed, by monitoring anti-tamper switches
the terminal is removed from the wall, by monitoring the anti-pulling
switches
When one of those event is detected, the MorphoAccess
®
J Series terminal acts
as required by the related configuration key (see section below):
Ignore the event (default) : usefull during normal maintenance operations
Send an alarm message to the Central Access Controller, through the usual
channel of the access control result messages (Wiegand, DataClock,
RS485, Ethernet or Wi-Fi
TM
.
Generate an audible alarm signal with the buzzer and a visual alarm signal
with the status LED.
Please refer to the MorphoAccess
®
J Series Installation Guide for more
information about the anti-tamper and the anti-pulling switches.