DOCUMENT SSE-0000077399-01 - VERSION 1.0 - MAY 2010 73
S
AGEM SÉCURITÉ DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
MORPHOACCESS® J SERIES User Guide Anti-tamper and anti-pulling switches
TERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATIONTERMINAL CUSTOMIZATION
The configuration key app/failure ID/alarm ID defines the value of the alarm
ID to send to Wiegand or Dataclock. This ID permits to distinguish between a
user ID and an error ID. To be validated, configuration key app/failure ID/
enabled must be set to 1.
In Wiegand and Dataclock the alarm ID is sent like other Failure Ids. See the
documentation MorphoAccess
®
Remote Messages Specification for a
description of the packet format in UDP and RS485.
Tamper Alarm Level
app/tamper alarm/level
0 Anti-pulling and anti-tamper switches ignored.
1 An alarm message is sent to the controller by the same channel as the
access control result message (if enabled).
2 In addition to previous level, the terminal buzzer outputs an audible alarm
signal, and the terminal status LED displays a red blinking light.
Tamper Alarm ID
app/failure ID/alarm ID
app/failure ID/enabled 1 (Enabled)
0 (0 - 2)
65535 (0 - 65535)
1