VM1000 Series
‐118‐
In addition, the life of the EEPROM is shortening since the EEPROM is stored
frequently. Therefore, you have only to change the value of RAM under
communication mode. It is no need to store some function code. (it can be achieved
as long as the high bit F of the function code address is changed into 0.The address
can only represent the writing RAM, can not act as the reading action. When reading,
it is invalid address).
6.6 Register Address
stop/running parameters:
Parameter Address Parameter Description
1000 communication setting value(decimal system)
1001 running frequency
1002 bus voltage
1003 output voltage
1004 output current
1005 output power
1006 output torque
1007 running speed
1008 DI input symbol
1009 DO output symbol
100A AI1 voltage
100B AI2 voltage
100C reserved
100D count value input
100E length input
100F load speed
1010 PID setting
1011 PID feedback