VM1000 Series
‐57‐
flashing) light on)
F5.00
DI1
terminal
function
Setting range050
1 indicates: forward
rotation(FWD)
Factory value has
been set as 0, namely
adopt two wiring
control mode 1
Factory value
remain
unchanged
F5.16
Terminal
control
mode
Setting range03
0 indicates: 2 wiring scheme
1
Factory value has
been set as 0, namely
adopt two wiring
control mode 1
Factory value
remain
unchanged
Table 4-4 Common Parameters Setting of FWD Start/Stop
4Operation Procedure
Steps Operation Panel display Indicator Note
Start
Connect DI1 and COM
Usually, it adopts one
manual switch or PLC
output
5- digit LED display
become non-flicker
from flicker when
operating
RUN Lights on
Refer to
3.1
Viewing
running
status
Press “”key, switch
display status in turn
There are four items of
default displayrunning
frequency,setting
frequency,bus
voltage,output current
Turn on the
Hz,A,V
separately or turn
them on in group
Refer to
3.1
Stop
Disconnect DI1 and
COM
5- digit LED display
become flicker from
non-flicker
RUN Light off
Refer to
3.1
Table 4-5 Running Procedures of FWD Start/Stop