ΙΙΙ
. Indoor unit
2. Specification
ΙΙΙ
10
Model
Power supply
Remark
Performance
Power
Others
Size
Panel
Function /
Option
Cooling
✻
1)
Heating
✻
2)
Cooling (High/Low)
Heating (High/Low)
Type
Output
Air flow rate
Cooling
Heating
Cooling
Heating
Liquid
Gas
Drain
Capacity
Sound Level
✻
3)
Fan output
Running current
Power input
Connecting pipe
Net weight
Shipping weight
Net dimension
(WxHxD)
Shipping dimension
(Carton/Case) (WxHxD)
Net weight
Shipping weight
Net dimension
(WxHxD)
Shipping dimension
(Carton/Case) (WxHxD)
Air filter
Auto restart
Auto change over
Centralized controller (On/Off)
Group/Individual control from R/C
Troubleshooting by L.E.D
Auto swing (Up/Down)
Max. installation ceiling height
Drain pump
Certifications
AVMKC020CA0 AVMKC032CA0 AVMKC040CA0 AVMKH020CA0 AVMKH032CA0 AVMKH040CA0
1, 208~230, 60
7000
2
-
-
32/29
-
Cross fan
13
205
0.18
-
35
-
1/4
1/2
11/16
33.1
39.7
38.2x7.09x15.4
46x11.9x18.4
7.72
13.7
46.5x1.38x18.1
49.6x5.67x21.2
O
No
No
Yes (Option)
Yes (Option)
Yes
Yes
7 11/16
Yes
UL & ULC
11000
3.2
-
-
36/32
-
Cross fan
14
265
0.20
-
40
-
1/4
1/2
11/16
33.1
39.7
38.2x7.09x15.4
46x11.9x18.4
7.72
13.7
46.5x1.38x18.1
49.6x5.67x21.2
O
No
No
Yes (Option)
Yes (Option)
Yes
Yes
7 11/16
Yes
UL & ULC
13500
4.0
-
-
38/35
-
Cross fan
16
283
0.23
-
45
-
1/4
1/2
11/16
33.1
39.7
38.2x7.09x15.4
46x11.9x18.4
7.72
13.7
46.5x1.38x18.1
49.6x5.67x21.2
O
No
No
Yes (Option)
Yes (Option)
Yes
Yes
7 11/16
Yes
UL & ULC
7000
2
7500
2.2
32/29
32/29
Cross fan
13
212
0.18
0.18
35
35
1/4
1/2
11/16
33.1
39.7
38.2x7.09x15.4
46x11.9x18.4
7.72
13.7
46.5x1.38x18.1
49.6x5.67x21.2
O
No
No
Yes (Option)
Yes (Option)
Yes
Yes
7 11/16
Yes
UL & ULC
11000
3.2
12000
3.5
36/32
36/32
Cross fan
14
283
0.20
0.20
40
40
1/4
1/2
11/16
33.1
39.7
38.2x7.09x15.4
46x11.9x18.4
7.72
13.7
46.5x1.38x18.1
49.6x5.67x21.2
O
No
No
Yes (Option)
Yes (Option)
Yes
Yes
7 11/16
Yes
UL & ULC
13500
4.0
14500
4.3
38/35
38/35
Cross fan
16
300
0.23
0.23
45
45
1/4
1/2
11/16
33.1
39.7
38.2x7.09x15.4
46x11.9x18.4
7.72
13.7
46.5x1.38x18.1
49.6x5.67x21.2
O
No
No
Yes (Option)
Yes (Option)
Yes
Yes
7 11/16
Yes
UL & ULC
Cooling only Heat pump
Btu/h
kW
Btu/h
kW
-
Watt
CFM
A
A
Watt
Watt
inch
inch
inch
lbs
lbs
inch
inch
lbs
lbs
inch
inch
-
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
inch
Yes/No
-
ø, V, Hz
2-1. 1-way cassette type
✻ 1) Indoor temperature : 80ºF DB, 67ºF WB / Outdoor temperature : 95ºF DB, 75ºF WB / Piping length : 30ft, no lift
✻ 2) Indoor temperature : 68ºF DB, 67ºF WB / Outdoor temperature : 45ºF DB, 43ºF WB / Piping length : 30ft, no lift
✻ 3) Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room.
3-1.Indoor unit_TM_E_06890 2/27/03 10:13 AM Page 10