EasyManua.ls Logo

Samsung MKV190CL2B/E01 - Page 129

Samsung MKV190CL2B/E01
250 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
To do list
1) Display function when Panel MAIN MICOM communication has error
1-1) If there is no answer for 10 seconds after the panel micom received the requirement of
communication, "Pc - Er" display on the panel PCB will be ON/OFF alternately until the
communication error is canceled. (0.5 sec ALL ON, 0.5 sec ALL OFF alternately)
5. Check the installation status
5-1. Function for failure diagnosis
5-1-2. Display function of Communication error
1-2) “Pc - Er” display on the Pantry Room Display will be ON/OFF alternately until the communication error
is canceled. (0.5 sec ALL ON, 1.5 sec ALL OFF alternately)
2) Display function when Panel MAIN MICOM OPTION has error
2-1) ”OP - Er” code is repeatedly ON/OFF until Option error settles down.