EasyManua.ls Logo

Samsung MKV190CL2B/E01 - Page 160

Samsung MKV190CL2B/E01
250 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. Self Diagnosis & Trouble Shooting
6-1. If the trouble is detected by self-diagnosis
To do list
Checking method of ICE Maker Sensor
resistance CN90 "1"(Brown) "7"(Gray)
- Compare the temperature table after the
measure.
Checking method of ICE Maker Sensor resistance
- Measure the voltage of Resistance R914(IC01 MICOM
#71) on PCB or CN90 "1"(Brown) J23 JUMMPER
- Compare the temperature table after the measure.
Measuring voltage of CN90-"1"(Brown) J23 JUMMPER are as below.
PCB Typical Ground
J23 JUMMPER
Is input voltage of IC01
MICOM #71 normal?
YES
NO
No trouble with PCB and
temperature sensor.
Recheck the bad contact of
the connection.
YES
Measuring voltage of IC01 MICOM #71,
CN90 - "1" (Brown) and J23 JUMMPER
from PCB typical Ground part are similar.
Check the measure on the voltage of
Resistance, R914 DUE to the SMD
MICOM
Check the iced-solder, solder
bridging, disturbed solder.