6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
6. Self Diagnosis & Trouble Shooting
To do list
230
PROBLEM
Trouble
Shooting Step 1
Trouble Shooting
Step 2
Possible Causes SOLUTION
Nothing
coming
out when
pressing the
Sparkling
Water
Dispenser
Lever
Water coming out
when pressing
the Water
Dispenser Lever
Function of Load
Condition Mode.
: It is displayed that
there is no detection for
both the Water Fill-Up
and the Water Empty
(R-10-, R-10-).
2. The Water Supply
Error is confirmed at
the Self Diagnostics
Mode.
: When pressing the
and
buttons for
8 seconds at the
same time, it will
display 94E.
Defective 5-Way
Valve
(No Water Supply)
1. Reset the CO2
Cylinder by pressing the
Sparkling Water button
() for 3 seconds
on the Display Panel and
reproduce the Sparkling
Water.
2. When both the Water
Fill-Up and the Water
Empty are not detected
(R-10-,R-10-) after
completing the
reproduction of the
Sparkling Water and
there is the Water Supply
Error, replace the Module.