6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
6. Self Diagnosis & Trouble Shooting
To do list
235
PROBLEM
Trouble
Shooting Step 1
Trouble Shooting
Step 2
Possible Causes SOLUTION
Nothing
coming
out when
pressing the
Sparkling
Water
Dispenser
Lever
1. Check it at the
Display Function of
Load Condition Mode.
: It is displayed that
there is no detection
for both the Water
Fill-
Up and the Water
Empty
(R-10-, R-10-).
2. When plugging out
the Hose () of the
5-Way Valve Input
Terminal and
pressing the Water
Lever, the Water
dispenses.
1. Defective
Housing(,)
Connection
2. Defective 5-Way
Valve (No Water
Supply)
1. Reconnect the
Housing(,).
2. Replace the Module.