SVR-1630 Installation and Connection
30
2004. 07. 2004 (v 1.0)
Samsung Techwin
9.1 Connecting and Configuring the Sensor
9.1.1 Specification
The sensor input of the SVR-1630 has the specifications and normal operating conditions as described
below.
No. of Input Circuits 16 Photocoupler Inputs
Input Type N.C, N.O supported
Sensor Dry Contact Sensor
Specification
Connection Connect the stripped wires to the Terminal Block.
Valid Input Pulse
Duration
Minimum 500ms
Electrical
Performance
Output Currents Typical DC 12mA
9.1.2 Connecting Sensor Input
For connection of sensor inputs S1 ~ S16, see the figure below. The figure below is an example of dry
contact sensor connection. For connecting or removing wires, see “Preparing and Connecting Wireson
page 29. For connecting sensors (Open Collector output, etc.) other than dry contact sensors, it is
necessary to contact the Samsung Techwin CS team.