BASIC
USER MANUAL
SINUS PENTA
17/97
2.3.2.4. MODULAR IP00 STAND-ALONE MODELS (S64-S90)
To obtain high-power inverters, the following individual modules are matched together:
- Control unit, containing the control board and ES842 board
- Power supply unit module, composed of a 3-phase power rectifier and its control and power supply circuits
- Inverter module, composed of an inverter phase and its control circuits
- Braking unit.
Four types of inverter modules are available:
- Basic version
- Version with integrated control unit
- Version with integrated auxiliary supply unit (to be used for those models which are not equipped with the power supply
module, Size S64, S74, and S84)
- Version with integrated splitter unit (to be used for the Penta sizes where parallel-connected inverter
modules are installed - Size S74, S75, S80, S84, S90).
Match the elements above to obtain the proper inverter dimensioning for your application.
CAUTION
Properly configure ES842 control board inside the control unit. When ordering the
inverter, always state the inverter configuration you want to obtain.
a) Control unit
The control unit can be installed separately from the inverter modules or inside an inverter module (this option must be
stated when ordering the inverter). Dimensions of the control unit (separate from the inverter).
EQUIPMENT
W
H
D
Weight
Dissipated
power
mm
mm
mm
kg
W
Control unit
222 410 189 6 100