- 39 -
3. Convergence service adjustment
Preparation
When adjusting the convergence of LCD panels, Convergence Adjustment Tool is required. This tool can be ordered
as a service parts. Parts No. shown below.
Mound Adjustment Tool on the LCD panel and adjust each panel convergence.
Make sure each Red, Green and Blue LCD panel unit has been correctly installed before performing convergence
adjustments.
[Note]
This convergence adjustment is especially designed for the service. It is not for the precise adjustment as the factory
adjustment.
Tool Name : Assy CG Adjust-MM7A
Service Part No.: 610 319 5414
Fig.8-1
Fig.8-2
Optical Adjustment
Fixing Screws for CG
Adjustment Tool
(M2.5 x 4) x 2
CG Adjustment Tool
H1
Move right with turning right
V1
Move up with turning right
H2
Move right with turning left
V2
Move up with turning left