- 9 -
ORDER REPLACEMENT LAMP
Type No. Service Parts No.
POA-LMP80 610 315
7689
Lamp Replacement
CAUTION :
DO NOT OPERATE A PROJECTOR WHILE ANY OF LAMPS
IS REMOVED. IT MAY RESULT IN MALFUNCTIONS, FIRE
HAZARD, OR OTHER ACCIDENTS.
When the life of the projection lamp of this projector draws
to an end, the LAMP1/2 REPLACE indicator lights yellow. If
this indicator lights yellow, replace the lamp with a new one
promptly.
Handle
Lamp covers
For continued safety, replace with a lamp of the
same type. Do not drop a lamp or touch a glass
bulb! The glass can shatter and may cause injury.
Allow a projector to cool, for at least 60 minutes be-
fore you open the Lamp cover. The inside of the
projector can become very hot.
Top Control
CAUTION
Screws
Handle
Screws
Notes on Lamp Replacement:
To maintain quality of picture (better balance of color
and brightness in the entire screen), we recommend
replacing all 2 lamps at a time.
These indicators light yellow
when the life of the projection
lamp draws to an end.
Lamps
Follow these steps to replace the lamp.
1
Turn off the projector and disconnect the AC plug. Allow
the projector to cool for at least 60 minutes.
2
Loosen each screws on the lamp covers with a screw-
driver, and remove them.
3
Loosen 4 screws of the lamps with a screwdriver and pull
out one lamp and another with grasping the handle.
4
Replace the lamps with new ones and tighten the 4 screws
back into position. Make sure that the lamps are set prop-
erly. Replace the lamp covers and tighten the screws.
5
Connect the AC power cord to the projector and turn on
the projector.
6
Reset the Lamp replace counter.
See "How to reset the Counter Timer".
WARNING : TURN OFF THE UV LAMP BEFORE OPENING THE LAMP COVER.
USE UV RADIATION EYE AND SKIN PROTECTION DURING SERVICING.

Table of Contents

Other manuals for Sanyo PLC-XF60A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XF60A and is the answer not in the manual?

Sanyo PLC-XF60A Specifications

General IconGeneral
Vertical scan range48 - 120 Hz
Horizontal scan range15 - 120 kHz
Projection technologyLCD
Contrast ratio (typical)1300:1
Projector native resolutionXGA (1024x768)
Keystone correction, vertical40 °
Keystone correction, horizontal30 °
Aspect ratio4:3
CompatibilityUXGA/SXGA/XGA/SVGA/VGA/Mac
Dimensions (WxDxH)518 x 252 x 606 mm
Power requirementsAC 100-240 V, 50/60 Hz
Lamp typeUHP
Lamp power300 W
Light source typeLamp
Noise level39 dB
Dot clock scanning frequency230 MHz
Microphone inYes
S-Video inputs quantity1
Power consumption (typical)900 W
Operating temperature (T-T)5 - 35 °C
Weight and Dimensions IconWeight and Dimensions
Weight24000 g

Related product manuals