- 44 -
v Video level adjustment
1 Receive the 16-step grey scale computer signal with
INPUT 2 [RGB] mode.
2 Enter the service mode and select group no. 200”.
3
Connect an oscilloscope to test point TP_GVID1(+)
and chassis ground (-). Select item no. 6and change
data value to adjust the amplitude to be 10.0 ±0.05Vp-p.
4
Connect an oscilloscope to test point TP_RVID1 (+)
and chassis ground (-). Select item no. 7and change
data value to adjust the amplitude to be 10.0 ±0.05Vp-p.
5
Connect an oscilloscope to test point TP_BVID1 (+)
and chassis ground (-). Select item no. 8and change
data value to adjust the amplitude to be 10.0 ±0.05Vp-p.
b Input adjustment
PC Input adjustment
1 Receive the 100% whole-white computer signal with
INPUT 2 [RGB] mode.
2 Enter the service mode and select group no. 784”.
3
Select item no. 0 and change data value from 0 (de-
fault) to “1”. The adjustment will be carried out automati-
cally and the data value changes to 2 when finishing the
auto-adjustment correctly.
If the data value changes to “-1”, take adjustment above
again until the data is “2”.
AV Input adjustment
1 Receive the 100% whole-white component signal with
INPUT 2 [Y/Cr/Cb] mode.
2 Enter the service mode and select group no. 783”.
3
Select item no. 0 and change data value from 0 (de-
fault) to “1”. The adjustment will be carried out automati-
cally and the data value changes to 2 when finishing the
auto-adjustment correctly.
If the data value changes to “-1”, take adjustment above
again until the data is “2”.
Electrical Adjustments
c DC adjustment
1 Receive the 16-step grey scale computer signal with
INPUT 2 [RGB] mode.
2 Enter the service mode and select group no. 200”.
3 Connect a digital voltmeter to test point TPV1G (+)
and chassis ground (-). Select item no.0 and change
data value to adjust voltage to be 6.5 ±0.1V.
4 Connect a digital voltmeter to test point TPV1R (+)
and chassis ground (-). Select item no.1 and change
data value to adjust voltage to be 6.5 ±0.1V.
5 Connect a digital voltmeter to test point TPV1B (+)
and chassis ground (-). Select item no.2 and change
data value to adjust voltage to be 6.5 ±0.1V.
6 Connect a digital voltmeter to test point TPV2G (+)
and chassis ground (-). Select item no.3 and change
data value to adjust voltage to be 7.5 ±0.1V.
7 Connect a digital voltmeter to test point TPV2R (+)
and chassis ground (-). Select item no.4 and change
data value to adjust voltage to be 7.5 ±0.1V.
8 Connect a digital voltmeter to test point TPV2B (+)
and chassis ground (-). Select item no.5 and change
data value to adjust voltage to be 7.5 ±0.1V.