- 46 -
⁄3 White balance adjustment (Lamp2)
Set projector with 1-lamp and Lamp 2 mode.
White balance adjustment-1 (PC)
1 Receive the 50% whole-white computer signal with IN-
PUT 2 [RGB] mode.
2 Enter the service mode and select group no. 202”.
3 Select item no.27 (Green), 28 (Red) or 29 (Blue),
and change data values respectively to make a proper
white balance.
White balance adjustment-2 (AV)
1 Receive the 100% whole-white component signal with
INPUT 2 [Y/Cb/Cr] mode.
2 Enter the service mode and select group no. 212”.
3 Select item no.24 (Green), “25 (Red) or 26 (Blue),
and change data values respectively to make a proper
white balance.
White balance adjustment-3 (AV)
1 Receive the 50% whole-white component signal with
INPUT 2 [Y/Cb/Cr] mode.
2 Enter the service mode and select group no. 212”.
3 Select item no.27 (Green), “28 (Red) or 29 (Blue),
and change data values respectively to make a proper
white balance.
Confirm that the same white balance is obtained in the
all of input mode.
⁄4 White uniformity adjustment
The color shading correction adjustment performed with
a color management software included in the CD-ROM
supplied with the product. Please see the manual for fur-
ther information such as installation and adjustments.
Electrical Adjustments
REAL COLOR MANAGER PRO ver. 1.0
Instruction Manual CD-ROM
Part No. : 610 319 5346 645 072 1120
⁄1 AV white balance adjustment-2
1 Set projector with 2-lamp mode.
2 Receive the 50% whole-white component signal with
INPUT 2 [Y/Cb/Cr] mode.
3 Enter the service mode and select group no. 210”.
4 Select item no.27 (Green), “28 (Red) or 29 (Blue),
and change data values respectively to make a proper
white balance.
⁄2 White balance adjustment (Lamp1)
Set projector with 1-lamp and Lamp 1 mode.
White balance adjustment-1
1 Receive the 100% whole-white component signal with
INPUT 2 [Y/Cb/Cr] mode.
2 Enter the service mode and select group no. 211”.
3 Select item no.24 (Green), “25 (Red) or 26 (Blue),
and change data values respectively to make a proper
white balance.
White balance adjustment-2 (AV)
1 Receive the 50% whole-white component signal with
INPUT 2 [Y/Cb/Cr] mode.
2 Enter the service mode and select group no. 211”.
3 Select item no.27 (Green), “28 (Red) or 29 (Blue),
and change data values respectively to make a proper
white balance.
White balance adjustment-3 (PC)
1 Receive the 50% whole-white computer signal with IN-
PUT 2 [RGB] mode.
2 Enter the service mode and select group no. 201”.
3 Select item no.27 (Green), “28 (Red) or 29 (Blue),
and change data values respectively to make a proper
white balance.
Confirm that the same white balance is obtained in the
all of input mode.

Table of Contents