- 50 -
Electrical Adjustments
Group No. Item Function Range Initial Value
0 Hi-Land SW 0:Normal Mode1: High-land Mode (Fan max speed continuously) 0 ~ 1 0
1 Not used Not used --
2 ANZEN FAN Control Fix SW 0:Normal 1:Normal Min2:Normal Max3:Eco Min4:Eco Max
142 Fan Parameter Setting
0 FAN_TEMP_A_WARNING
Temperature A to judge Abnormal Temp. (memorized) Outside
43
1 FAN_TEMP_B_WARNING
Temperature B to judge Abnormal Temp. (momorized) on Panel
60
2 FAN_TEMP_C_WARNING Voltage C to judge Abnormal Temp. (momorized) arround
Panel
55
3 Not used --
4 Not used --
5 Control Switch All 0:Auto-control all of FANs 1: Manual Control all of FANs 0 / 1 0
6 FAN A Manual Out Fan voltage in the manual mode 0~2000
7 FAN B Manual Out Voltage= Value/100 0~2000
8 FAN C Manual Out Effective FAN_CONTROL_SW=1 0~2000
9 FAN D1 Manual Out Step in 10, 0.1V 0~2000
10 FAN D2 Manual Out 0~2000
11 FAN EManual Out 0~2000
12 Temp Source Range High High and Low control limit value at Temp. sensor A 30 ~ 100 41
13 Temp Source Range Low Temp. =Value/10 0 ~ 100 27
14 Temp Fan-Out Range High High and Low Fan voltage value at Temp. sensor A 0~2000 1400
15 Temp Fan-Out Range Low Voltage = Value/100 0~2000 0
16 Not used --
17 Not used --
18 Not used --
19 Not used --
20 Presss Source Range Low High and Low control limit value at Atmosphere Sensor 0~1024 515
21 Presss Source Range High Note: Low is Fan add Max point accually 0~1024 745
22 Press FanAdd Range High High and Low Fan Voltage value at Atmosphere Sensor 0~255 35
23 Press FanAdd Range Low Voltage = Value/100 0~255 0
24 Ceil-Add Additional Voltage at Ceiling use Voltage = Value/100 0~2000 0
149 PJ Filter Reset Times
0 FILTER_CLR_CNT Reset times of the airfilter timer counter
150 Shippment Setting
0 Shippment Setting All of settings are set to default when the value changes to 10 0 ~ 10 0
160 Shootout
0 Switch 0:Off, 1:On 0 / 1 0
170 Smoke Resist Fan
0 Smoke Fan1 Speed Monitor Fan speed 1monitor of Smoke resister --- ---
1 Smoke Fan2 Speed Monitor Fan speed 2monitor of Smoke resister --- ---
2 Smoke Fan Speed Control
Set speed for Smoke resister 0:Normal / 1:MAX fixed / 2:USER(setting
enable on 170-3)
0 ~ 2 0
3 Smoke Fan Speed Setting
Set speed of user setting for Smoke resister (Effective only 170-2 is
2 (USER)
0 ~ 50 20
4 Smoke fan Setting Speed Monitor Monitor at current setting -- --
5 Smoke Fan Speed Mini. Duty Value Display Duty value at minimum temp. for Auto-Fan Control 20
6 Smoke Fan Speed Max. Duty Value Display Duty value at maximum temp. for Auto-Fan Control 50
7 Smoke Fan Speed Min. Temp. Sets minimum temp. for Auto-Fan Control 0 ~ 99 27 (Not momorized)
8 Smoke Fan Speed Max. Temp. Sets maximum temp. for Auto-Fan Control 0 ~ 99 40 (Not momorized)
9 Smoke Box Time Counter Reset Times Reset times of the Smoke Box time counter
10 Smoke Box use time Accuurated use time of the Smoke Box
11 Smoke Box Version “9999” upper 2 digits for Main version, lower for Sub version
171 Smoke Box Fan: Calibration
0 Execute calibration of Fan Speed 1: Execute Calibration, 2: Complete, -1: Error -1 ~ 2 0
1 Smoke Fan1: result Offset Smoke Fan1: result of cloggled filter calibration, Offset value
2 Smoke Fan1: result Min. Smoke Fan1: result of cloggled filter calibration, Min. Fan Speed
3 Smoke Fan1: result Max. Smoke Fan1: result of cloggled filter calibration, Max. Fan Speed
4 Smoke Fan2: result Offset Smoke Fan2: result of cloggled filter calibration, Offset value
5 Smoke Fan2: result Min. Smoke Fan2: result of cloggled filter calibration, Min. Fan Speed
6 Smoke Fan2: result Max. Smoke Fan2: result of cloggled filter calibration, Max. Fan Speed
7 Smoke Fan Calibration OK Times Succeed times of the Smoke Box Calibration
8 Air Pressure at Smoke Filter Calibration Air Pressure at Smoke Filter Calibration
180 DDC Setting
0 HDCP EDID Data Setting 0:EDID Data for DVI / 1:EDID Data for HDCP 0 / 1 0
190 Mecha Shutter
0 Warming up option 0:Warming up Enable1:Warming up Disable 0 / 1 0
200 Panel Adjustment PC [Lamp ALL] XGA[SXGA]
0 A03(IC571)V1G DAC Video Center G L (IC571 16pin) 0 ~ 255 84 [80]
1 A01(IC571)V1R DAC Video Center R L (IC571 14pin) 0 ~ 255 84 [80]
2 A05(IC571)V1B DAC Video Center B L (IC571 18pin) 0 ~ 255 84 [80]
3 A04(IC571)V2G DAC Video Center G H (IC571 17pin) 0 ~ 255 144 [143]