-43-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
0 Vsync input
0
0 - 1 0: Enable / 1:Disable
1 Timer for Recovery starting
0
0 - 1 0: Enable / 1:Disable
2 Color correction
0
0 - 1 0: Enable / 1:Disable
3 SPI receiver
0
0 - 1 0: Enable / 1:Disable
4 UART(UPUside)
0
0 - 1 0: Enable / 1:Disable
5
3Wire serial command gen-
erator
0
0 - 1 0: Enable / 1:Disable
6 Outputof 3 wire serial I/F
0
0 - 1 0: Enable / 1:Disable
7 ColorCorrectionTable_R
1878 / 1878
0 - 4095 AV / PC
8 ColorCorrectionTable_R
1878 / 1878
0 - 4095 AV / PC
9 ColorCorrectionTable_R
1878 / 1878
0 - 4095 AV / PC
10 ColorCorrectionTable_R
1977 / 1977
0 - 4095 AV / PC
11 ColorCorrectionTable_R
2044 / 2044
0 - 4095 AV / PC
12 ColorCorrectionTable_R
2048 / 2048
0 - 4095 AV / PC
13 ColorCorrectionTable_R
2048 / 2048
0 - 4095 AV / PC
14 ColorCorrectionTable_R
2048 / 2048
0 - 4095 AV / PC
15 ColorCorrectionTable_R
2048 / 2048
0 - 4095 AV / PC
16 ColorCorrectionTable_R
2048 / 2048
0 - 4095 AV / PC
17 ColorCorrectionTable_G
1612 / 1612
0 - 4095 AV / PC
18 ColorCorrectionTable_G
1612 / 1612
0 - 4095 AV / PC
19 ColorCorrectionTable_G
1612 / 1612
0 - 4095 AV / PC
20 ColorCorrectionTable_G
1842 / 1842
0 - 4095 AV / PC
21 ColorCorrectionTable_G
1974 / 1974
0 - 4095 AV / PC
22 ColorCorrectionTable_G
1966 / 1966
0 - 4095 AV / PC
23 ColorCorrectionTable_G
2015 / 2015
0 - 4095 AV / PC
24 ColorCorrectionTable_G
2034 / 2034
0 - 4095 AV / PC
25 ColorCorrectionTable_G
2048 / 2048
0 - 4095 AV / PC
26 ColorCorrectionTable_G
2048 / 2048
0 - 4095 AV / PC
27 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
28 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
29 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
30 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
31 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
32 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
33 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
34 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
35 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
36 ColorCorrectionTable_B
2048 / 2048
0 - 4095 AV / PC
37 VSYNC pulse width
13
0 - 4095
38 Vsync generation interval
313
0 - 1023
39 SCIOUT L-period
7
0 - 255
40 Interval setting for recovery
8
0 - 1023
Group
200
Option
0
Logo Prohibition
Logo Prohibition (0: Menu, 1: Forced) 0 0 - 1 Effective after AC On
1 RS232C Baudrate Baud Rate 0 0 - 2
0: 19200bps, 1: 9600bps,
2: 115200bps
2 PJLink Enable PJLink 1 0 - 1 0: Disable 1: Enable
4 CABLE SW Long Cable 0 0 - 1 0: Disable, 1: Enable
5
PW Debug Command
Enable
0 0 - 1
0:Disable (Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
40
Lamp PWM PresAv
50Hz
80 0-255
41
Lamp PWM PresAv
60Hz
67 0-255
42
Lamp PWM PresUnlock
65 0-255
43
Lamp PWM PresPcA
2 0-255
44
Lamp PWM PresPcB
3 0-255
45
Lamp PWM
PrefHAv50Hz
5000 0-65535
46
Lamp PWM
PrefHAv60Hz
5000 0-65535
47
Lamp PWM PrefHUnlock
5000 0-65535
50
Lamp Replacement
Display
1 0-1

Table of Contents

Other manuals for Sanyo PLC-XU4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XU4000 and is the answer not in the manual?

Sanyo PLC-XU4000 Specifications

General IconGeneral
BrandSanyo
ModelPLC-XU4000
CategoryProjector
LanguageEnglish

Related product manuals