EasyManuals Logo

Sanyo PLC-XU4000 Service Manual

Sanyo PLC-XU4000
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
-6-
Circuit Protections
The projector will be automatically turned off when the internal temperature of the projector is abnormally high, or the
cooling fans stop spinning, or the power supplies in the projector are failed.
Warning temperature and power failure protection
The projector is shut down and the WARNING indicator lights red.
When the projector detects an abnormal condition, it is automatically shut down to protect the inside of the projector
and the WARNING indicator lights red. In this case, unplug the AC power cord and reconnect it, and then turn the
projector on once again to verify operation.
WARNING
DO NOT LEAVE THE PROJECTOR WITH THE AC POWER CORD CONNECTED UNDER AN
ABNORMAL CONDITION. IT MAY RESULT IN FIRE OR ELECTRIC SHOCK.
4Note:
- If the WARNING indicator lights red, it may defect the cooling fans or power supply circuits. Check fans operation
and power supply lines referring to the chapter “Power supply & protection circuit” and "Fan control circuit" in the
Chassis Block Diagram section.
When the temperature inside the projector reaches a certain level, the projector will be automatically shut down to
protect the inside of the projector and the WARNING and POWER indicators start blinking. When the projector has
cooled down enough (to its normal operating temperature), the POWER indicator stops blinking and lights red, The
projector can be turned on again by pressing the ON/STAND-BY button.
4Note:
The WARNING indicator continues to blink even after the temperature inside the projector returns to normal. When
the projector is turned on again, the WARNING indicator stops blinking.
Check items
- Remove dust arround the air filter.
- Ventilation slots of the projector are blocked. In such an event, reposition the projector so that ventilation slots are
not obstructed.
- Check if projector is used at higher temperature place (Normal operating temperature is 5 to 35 ˚C or 41 to 95˚F)
The projector is shut down and the WARNING indicator is blinking red.
LED indicator
WARNING
indicator
POWER
indicator

Table of Contents

Other manuals for Sanyo PLC-XU4000