20 MICRA SATEL
Blocking – option available for the communication device mode. If enabled, the zone will
function as a blocking zone, i.e. its violation will result in blocking other zones of the
module. Only one module zone from among the wired and wireless ones can perform
the function of blocking zone.
Blocked – option available for the communication device mode. If enabled, the zone will
be blocked upon violation of a blocking zone or after receiving by the module of
a suitable control command in SMS message (content of the command being defined in
the "Bypass" field).
Zone type – parameter available for the alarm device mode. One of the zone types
described in section "Wired zones" can be selected. You can make your selection in the
dropdown menu which will be displayed after a right-click of your mouse, or by entering
the digit corresponding to the zone type.
Output 1 / 2 – fields available for the communication device mode. They allow you to
define, if and how the zone will control the output. Click on the field twice to display
successively:
– blank field – zone does not control the output,
– ON – violation of the zone will activate the output,
– ON for time – violation of the zone will activate the output for a defined time (cut-off
time must be defined for the output),
– OFF – violation of the zone will deactivate the output.
Presence check – select the field (the field is selected, when the "x" symbol is shown in
it), if the module is to control presence of the detectors. The module will then analyze
the transmissions sent periodically by the detectors. In the field, the number of packets
received during the last transmission will be shown in parentheses (up to 18). In the
main menu, under the fields corresponding to the particular wireless zones, bars will
appear to illustrate the quality of communication. The shorter the bar and the lower the
number in parentheses, the lower the communication quality. If the field is selected and
the module receives no transmission from a detector for one hour, a trouble will be
reported by the module – the suitable message will be displayed in the GPRS-SOFT
program (default: the option is disabled).
New detector – the button allows you to add a wireless detector (see: Adding new
wireless devices). If a detector has already been added in the given position, a window
will open with a prompt, whether the detector should be replaced with a new one. If the
answer is affirmative, click "OK" to bring up the new detector adding window. The type
and serial number will be replaced, but the name and the zone type assigned to the old
detector will be retained.
Remove detector – the button allows you to remove a wireless detector (see: Removing
wireless devices).
Test Mode ON / OFF – the button allows you to start / end the test mode in the module.
The test mode enables the wireless detectors to be checked for correct functioning.
Detector violation will result in setting the module relay outputs to 300 ms (it applies to
all output types, except for the "no" type). If a signaling device is connected to the
output, each violation of the detector will be suitably signaled. On starting the test mode,
the bars indicating the quality of communication in the main menu will change their color
to red, and number 0 will be displayed in the "Presence check" fields. Only after
receiving transmission from a wireless detector will the information on communication
quality be displayed. The test mode will automatically be ended after 30 minutes.
Arming will end the test mode.
Note: Starting the test mode has no other effect on the operating of MICRA module.