43
11063344 • Rev EA • Dec 2012
H1 Axial Piston Pump, Size 045/053, Single
Technical Information
Installation Drawings
Please contact Sauer-Danfoss for specic installation drawings
Installation Drawings
(continued)
Speed and Temperature Sensor, option H for mounting ange option K
Speed and Temperature Sensor
Speed sensor connector
Deutsch DTM04-6P
Paint free
107.6 ±0.8
125.2 ±2.5
1 ±0.5
9.7
0
-0.5
R0.8 max
45°±5°
101.6
0
-0.05
Mounting ange
Flange 101-2
Per ISO 3019-1 (SAE B)
Paint free
2x ∅14.3
+0.25
-0.13
2x 73 ±0.25
19.8 ±2.1
106 ±0.8
23 ±0.5
P700 33 206
Z
mm
1 3
46
ASSIGNMENTPIN
1 Output signal 2
2 Direction
3 Output signal 1
4 Supply
5 Ground
6 Temperature
Speed sensor
Connector
Z (2:1)
P301 310