17.
Align the particulate filter outlet for the dif-
ferential pressure sensor with the mark.
Tighten the V-clamp and the band clamp
around the particulate filter. Tightening
torque, V-clamp, 20 Nm.
18. Clean the sealing surface on the end plate (3).
The surface should be free of gasket residue.
19. Fit the end plate and V-clamp (2) which hold
the end plate in place. Tightening torque, V-
clamp, 20 Nm.
20. Fit the V-clamp at the particulate filter outlet
(1). Tightening torque, V-clamp, 20 Nm.
21. Fit the exhaust gas temperature sensor (1).
Use 2 290 856 17 mm, Special sleeve, slot-
ted, 1/2" if necessary. Tightening torque, Ex-
haust gas temperature sensor, T4010, 30 Nm.
22. Connect the differential pressure sensor har-
ness-to-component connector (2).
IMPORTANT!
Be careful when handling the sensor body. It is
sensitive and must not be bent or straightened.
Renew the sensor if it is bent.