OPM 100 en-GB 106
© Scania CV AB 2023, Sweden
Other
12.
Fit the bracket nut and differential pressure
sensor connections.
13. Clean the sealing surface of the oxidation
catalytic converter (1). The surface should be
free of gasket residue.
14. Fit new gaskets (2) to the sealing surfaces on
the particulate filter (3) and the oxidation
catalytic converter (1).
15. Fit the new particulate filter. Use a jack or
similar to support the particulate filter.
16. Fit the V-clamp (2) and the band clamp (1)
loosely around the particulate filter.