OPM 100 en-GB 105
© Scania CV AB 2023, Sweden
Other
9.
Remove the differential pressure sensor and
its bracket from the old particulate filter as
described below:
a) Tilt up the bracket and the differential
pressure sensor (1).
b) Pull off the bracket from the slot in the
particulate filter (2).
10. Remove one hose with accompanying pres-
sure pipe from the differential pressure sen-
sor and blow them clean using compressed
air and 99 405 Clutch bleeder. Refit the hose
and pressure pipe before removing the next
one for cleaning with compressed air.
Make sure that the hoses are not mixed up when
they are fitted on the differential pressure sensor.
11. Refit the differential pressure sensor and its
bracket on the new particulate filter as de-
scribed below:
a) Push in the bracket into the slot (1).
b) Tilt in the bracket and the differential
pressure sensor against the particulate fil-
ter (2).