Scania DC09 - SCR System Fault Reaction and Torque Reduction

Scania DC09
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Starting and driving
OPM 100 en-GB 35
© Scania CV AB 2023, Sweden
Reaction to fault in the SCR system – EU
Stage IIIB/IV/US Tier 4i/Tier 4f
If a new fault occurs within 40 hours of opera-
tion since the first fault, the warning lamp will
come on. After 30 minutes of operation, the
warning lamp will flash rapidly and torque will
be reduced to 0% (low idling) within 30 minutes.
Once the fault has been remedied and the engine
management system has received an indication
that the exhaust gas aftertreatment system is op-
erational, i.e. when the fault code has been ac-
knowledged in SDP3, torque returns to the
normal level.
IMPORTANT!
If the torque has been reduced to 0% (low
idling), the control unit does not detect that the
SCR system is functioning again. A service tech-
nician must then reset the system so that the
torque returns to the normal level.
Note:
The torque reduction only applies to engines cer-
tified according to US Tier 4. Some emergency
vehicles do not have torque reduction.
Time Warning
lamp
Torque reduction
1
1. Only applies to engines certified according to US Tier 4.
Fault detect-
ed
Constant
light
After 30
minutes
Flashing Torque is reduced by
1% per minute to
70 % of the highest
torque.
After 4 hours Flashing rap-
idly
Torque is reduced to
0% (low idling)
within 2-10 minutes.
319 563
Symbol for fault in SCR system.