EasyManua.ls Logo

Schiedel CM03 - User Manual

Default Icon
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operating Manual 90° ACTUSAFE CMF(S)QT
OM-ENGLISH-Failsafe-QT-16xx-V2.00-2022.03.01

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Schiedel CM03 and is the answer not in the manual?

Summary

Safety Instructions

Introduction

Functional Description of the CMF(S)QT - Failsafe Drive

Failsafe-direction

Defines the two possible failsafe directions (CW and CCW) for the actuator.

General Information

Serial number

Explains how to find and use the actuator's serial number for identification.

Protection class

Details the protection class rating of the actuator and its implications.

Mounting position

Provides guidance on the recommended mounting positions for the actuator.

Direction of rotation

Explains the standard and alternative directions of rotation for the actuator.

Protective devices

Outlines the protective devices integrated into the actuator.

Ambient temperature

Specifies the acceptable ambient temperature range for actuator operation.

Delivery condition

Describes the state of the actuator upon delivery and initial checks.

Information notice (tag)

Details the information provided on the actuator's identification tag.

Transport and Storage

Installation Instructions

Mechanical connection

Covers the procedure for physically connecting the actuator to the valve.

Commissioning

General information

Provides general information and technical data before commissioning.

Manual operation

Describes how to operate the actuator manually using the handwheel.

Mechanical default setting, preparation

Covers the default mechanical settings and preparation steps.

Setting the end positions

Guides on how to set the electrical and mechanical end positions.

Setting the mechanical end stop

Explains the adjustment procedure for the mechanical end stop.

Adjusting of Failsafe speed

Details how to adjust the failsafe speed of the actuator.

Final work

Outlines the final steps after commissioning and adjustments.

Control Unit

Operating unit

Describes the components and functions of the actuator's operating unit.

Display elements

Explains the graphic and LED display elements used for status information.

Operation

Details how to operate the actuator using switches and interfaces.

Welcome Menu and Operation Modes

Covers welcome menu, settings, operation modes, configuration, and TEACHIN function.

Maintenance

Technical data Failsafe brake

CM03 F(S)QT Data

Lists the technical data for the CM03F(S)QT failsafe brake.

CM06 F(S)QT Data

Lists the technical data for the CM06F(S)QT failsafe brake.

CM12 F(S)QT Data

Lists the technical data for the CM12F(S)QT failsafe brake.

Spare parts

Lubricant recommendation; Lubricant requirements

Lubricant points F(S)QT

Details the specific lubrication points and quantities for F(S)QT actuators.

Basic lubricant service interval

Outlines the basic service intervals for actuator lubrication based on operating conditions.

Training

Mode of operation F(S)QT

CM03 F(S)QT Modes

Describes the different operating modes for the CM03 F(S)QT actuator.

CM06 F(S)QT Modes

Describes the different operating modes for the CM06 F(S)QT actuator.

General Actuator Information

Overview

Provides a general overview and identification of the actuator components.

Serial number and type label

Explains how to identify the actuator using its serial number and type label.

Operating mode

Details the actuator's suitability for different operating modes (open/closed-loop, continuous).

Protection class

Specifies the actuator's protection class and conditions for its effectiveness.

Mounting position

Offers advice on optimal mounting positions, especially for outdoor use.

Direction of rotation

Defines the standard directions of rotation for opening and closing the valve.

Protection devices

Outlines the integrated protection devices such as torque monitoring.

Ambient temperature

Specifies the operating temperature ranges for different actuator types.

Delivery condition of the actuators

Describes the final inspection and delivery status of the actuators.

Information notice (tag)

Details the information provided on the actuator's identification tag.

Packaging, transport and storage

General

Mentions silica gel in the connection compartment and its removal.

Storage

Provides measures to prevent damage during actuator storage.

Long-term storage

Gives instructions for storing actuators for periods longer than six months.

Installation instructions

Mechanical connection

Details the procedure for physically connecting the actuator to the valve.

Mounting position of the operating unit

Explains how to adjust the mounting position of the actuator's control unit.

Electrical connection

Provides instructions for making electrical connections, including power supply.

Commissioning

General

General notes and requirements before starting the commissioning process.

Manual operation

Describes how to operate the actuator manually using its handwheel assembly.

Mechanical default settings, preparation

Covers mechanical settings and preparation before motorised operation.

User Level and Permissions

Explains user levels and their permissions for parameter access.

End limit setting

Guides on setting the actuator's end limits for OPEN and CLOSE positions.

Final works

Outlines the final steps after commissioning, including checks and sealing.

Control Unit

Operating unit

Describes the components and functions of the actuator's operating unit.

Display elements

Explains the graphic and LED display elements used for status information.

Operation

Details how to operate the actuator using switches and interfaces.

Welcome Menu and Operation Modes

Covers welcome menu, settings, operation modes, configuration, and TEACHIN function.

Parameter menu

Parameter group: End limit

Covers parameters for configuring end positions and switch-off behavior.

Parameter group: Torque

Details parameters related to torque settings for actuator operation.

Parameter group: Speed

Explains parameters for setting actuator speed in different modes.

Parameter group: Ramp (optional)

Covers parameters for setting the motor start ramp.

Parameter group: Control

Details parameters related to control functions like ready delay and auxiliary output.

Parameter group: User Level

Explains user levels and their impact on parameter access and modification.

Parameter group: Position

Covers parameters for defining intermediate and emergency positions.

Parameter group: Binary inputs

Details the configuration and function of the actuator's binary inputs.

Parameter group: Binary outputs

Explains the configuration and function of the actuator's binary outputs.

Parameter group: Position output (optional)

Covers parameters for setting up the analog position output.

Parameter group: Step mode

Details parameters for setting up step mode operation for extended travel.

Parameter group: Positioner (optional)

Explains parameters for the optional positioner function.

Parameter group: PID controller (optional)

Details parameters for the optional PID controller function.

Parameter group: Characteristic curves (optional)

Covers parameters for enabling torque, speed, and valve characteristic curves.

Parameter group: Identification (optional)

Allows entering custom identification parameters like PPS number.

Parameter group: System parameters

Covers parameters for actuator configuration and service information.

Parameter group: Miscellaneous

Includes parameters for language, smartcode, backup, and info display.

Default User Level Settings

Shows default user level settings for parameters, controlling access and modification.

Status area

Status

Presents current process, diagnostic data, and status of outputs and inputs.

History

Shows logged history entries, including warnings, errors, and status changes.

Infrared connection

Bluetooth connection

Maintenance

Troubleshooting

History Entries

Lists all possible history entries with their types and descriptions.

Fuses

Lubricant recommendation; Lubricant requirements

Main body: -25 to +60°C

Lubricant recommendations for the main body within a specific temperature range.

Main body: -40 to +60°C

Lubricant recommendations for the main body at lower temperatures.

Output type A and spindle drives -40 to +60°C

Lubricant recommendations for output type A and spindle drives.

Basic lubricant service interval

Outlines the basic service intervals for actuator lubrication based on operating conditions.

Training

Original Declaration of Incorporation of Partly Completed Machinery

Declaration of Conformity

Declaration of Conformity

Technical data

Binary outputs

Provides technical specifications for the actuator's binary outputs.

Binary inputs

Provides technical specifications for the actuator's binary inputs.

Analog inputs

Details the specifications for the analog inputs of the actuator.

Analog output

Provides technical specifications for the analog output of the actuator.

Auxiliary voltage input and output

Lists technical data for auxiliary voltage inputs and outputs.

Connections

Describes the types of connections for explosion-proof and non-explosion-proof versions.

Mode of operation CM

Details the various modes of operation for CM actuators.

Mode of operation CM03 + QT

Specifies the operating modes for CM03 + QT actuator variants.

Mode of operation CM03 + L

Outlines the operating modes for CM03 + L actuator variants.

Mode of operation CM03 + LK

Details the operating modes for CM03 + LK actuator variants.

Miscellaneous

Covers miscellaneous technical specifications like ambient temperature and color.

Technical data CM03

Standard version CM03

Provides technical specifications for the standard CM03 actuator.

24 VDC version CM03

Lists technical data for the 24 VDC version of the CM03 actuator.

400 V version CM03

Details technical data for the 400 V version of the CM03 actuator.

Technical data CM06

Standard version CM06

Provides technical specifications for the standard CM06 actuator.

400 V version CM06

Lists technical data for the 400V version of the CM06 actuator.

Technical data CM12

Standard version CM12

Provides technical specifications for the standard CM12 actuator.

Characteristic curves

Characteristic curves - CM03

Displays characteristic curves for the CM03 actuator.

Characteristic curves - CM06

Displays characteristic curves for the CM06 actuator.

Characteristic curves - CM12

Displays characteristic curves for the CM12 actuator.

Schiedel CM03 Specifications

General IconGeneral
BrandSchiedel
ModelCM03
CategoryFireplace Accessories
LanguageEnglish