Maintenance
24 01.00 | CMS | Assembly and operating manual | en | 1553577
7 Maintenance
7.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
7.2 Maintenance intervals
Maintenance interval Maintenance work
regularly (on each change) Perform a visual inspection. The
product must be free of swarf
and dirt.
1000 changing processes *) Clean all parts thoroughly, check
for damage and wear.
Oil or grease external steel parts.
Grease suspended bolts at the
contact surfaces to CMS -K and
CMS-A.
as required Send damaged products to
SCHUNK for repair.
*) Information refers to use under normal operating and ambient
conditions.
7.3 Lubricants/Lubrication points
During maintenance, treat all greased areas with lubricant.
Thinly apply lubricant with a lint-free cloth.
SCHUNK recommends the lubricants listed.
Lubricant point Lubricant
Metallic sliding surfaces Rivolta F.L.G. GT-2
The product contains food-compliant lubricants as standard.
The requirements of standard EN1672-2:2020 are not fully met.
NOTE
l
Change contaminated food-compliant lubricant.
l
Observe information in the safety data sheet from the
lubricant manufacturer.