PUSH
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
THE OPERATION AND FUNCTION OF THE DURESS CODE
The Duress Code(s) has double actions when it is keyed in. It activates the Duress Output (for duress alarm) and at the same time
activates the speficic Relay Output 1, 2 or 3 just like a normal User PIN. The Duress Code always activates its Relay Output in its
group, but, does not de-activate (stop) the Duress Output. ONLY a normal User PIN in any one of the user groups, or a Super User
PIN can reset (de-activate) the Duress Output.
FOR EXAMPLE:
Key in The Duress Code 3369 of the Group 1 (for Output 1) To Command The Duress Function :
3369 # ----- Duress Output activates (switches to ( - ) ground) & Output 1 activates.
Key in The Duress Code 3369 in Group 1 (for Output 1) Again :
3369 # ----- Duress Output keeps activating and no change in its state (keeps to (-) ground) & Output 1 activates again.
Key in A Normal User PIN 1369 in Group 1 (for Output 1):
1369 # ----- Duress Output resets (back to OFF state) but has no function on Output 1.
CONFIGURATION OF THE OUTPUT MODES OF OUTPUT 1 , 2 AND 3 (Locations 51, 52 & 53)
The three relay outputs of this keypad are programmable for Start/Stop or Timing modes. Apart from the door access control,
alarm arm-disarm control, they are also universal timers for automatic operators in industry with their 99,999 seconds (over 24
hours) programmable timer.
LOCATIONS OUTPUT MODE & TIME VALIDATION
51-53 0 or 1- 99999 #
OUTPUT LOCATIONS
51 -- Location for Output 1
52 -- Location for Output 2
53 -- Location for Output 3
OUTPUT MODE & TIMING
0 – Start /Stop Mode (Toggle)
The number 0 sets the output to the Start / Stop mode . The output Starts when an User PIN is entered; the output Stops when an
User PIN is entered again.
1 - 99999 Seconds Momentary --- (Default -- Momentary 5 Seconds)
The output can be set in Momentary Mode with the time of 1 second to 99,999 seconds. The output will reset automatically when
the time expires OR it can be RESET manually at anytime with the Super User Code that operates the desired output before the
end of the time.
Example :
Reset Output 1 -- SUPER USER CODE # 1 ------------- Output 1 resets
Reset Output 2 -- SUPER USER CODE # 2 ------------- Output 2 resets
Reset Output 3 -- SUPER USER CODE # 3 ------------- Output 3 resets
PERSONAL SAFETY AND SYSTEM LOCK - OUT (Location 60)
LOCATION LOCK-OUT MODES VALIDATION
60 1 to 2 Digits #
SAFETY & LOCK-OUT OPTIONS
The Options are represented by their Mode Numbers in programming. They are described below:
1 --- After 10 successive false User Code trials, the keypad locks during 60 seconds. -- (Default)
2 --- After 10 successive false User Code trials, activates the Duress output to switch to (-) ground.
The Duress Output can be released with any user PIN in the User Group 1 or the Super User PIN.
43Rev. 01 - 05/201167411245