Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
PUSH
English
REFRESH THE SYSTEM WITH THE “REFRESHING CODE ” - - - 9999
The system can be refreshed to clear all the old data stored and back to its ex-factory default values.
IMPORTANT NOTE:
Make sure that you really want to clear ALL the OLD data before entering of the Refreshing Code. The keypad will be back with its
default values like a new unit. Re-program of the desired values are necessary.
REFRESHING CODE VALIDATION
9999 #
REFRESHING CODE
• The Code 9999 is for refreshing of the system. Once it is keyed in and validated with #, all the values programmed previously will
be cleared EXCEPT the Master Code .
• The refreshing takes around 2.5 minutes. During the keypad is being refreshed the Status LED (Amber) ashes fast until the end.
THE DEFAULT VALUES OF THE KEYPAD
PROGRAMMING
LOCATION PARAMETERS DEFAULT FUNCTIONS & VALUES
01 Master Code 0000 Factory Set, Not a default value *
02 Super User PINs Nil ----- User Program Required
10 User PINs for O/P 1 Nil ----- User Program Required
20 User PINs for O/P 2 Nil ----- User Program Required
30 User PINs for O/P 3 Nil ----- User Program Required
40 Visitor Codes Nil ----- User Program Required
41 Duress Code for O/P 1 Nil ----- User Program Required
42 Duress Code for O/P 2 Nil ----- User Program Required
43 Duress Code for O/P 3 Nil ----- User Program Required
51 O/P Mode of The O/P 1 Time = 5 Sec, Momentary
52 O/P Mode of The O/P 2 Time = 5 Sec, Momentary
53 O/P Mode of The O/P 3 Time = 5 Sec, Momentary
60 Personal Safety & Lock-out Code = 1, 10 False Code Lock-out 60 Sec
70 User Code Entry Mode Code = 2, Manual Entry Mode
71 Pacier Tones ON-OFF Selection Code = 1, Pacier Tone ON
72 O/P Operation Announcer Code = 1 Sec, Notication Beep ON
73 Status LED Standby Flashing ON-OFF Code = 1, Flashing Enabled
80 Door Forced Open Warning & Timing Code = 0, Warning Disabled
81 Door Propped-up Warning & Delay Code = 0, Warning Disabled
90 Egress Delay & Warning Code 1 = 0, Instant, No Delay
Code 2 = 1, Momentary Contact without Warning
91 Door Opening Alarm & Timer Code = 0, Alarm O/P Disabled
94 Operation Modes & Wiegand Output Code = 0, Wiegand O/P for Valid Code Only
NOTE:
The DAP Code 8080 and the Refreshing Code 9999 are fixed in the operating system program. It can not be changed in any ways
or be inuenced by the system in default setting.
35Rev. 01 - 05/201167411245